Manufacturers

Fluke 355 AC/DC Clamp Meter

  • Model: FK 355
  • Shipping Weight: 0.814kg
  • Manufactured by: FLUKE

RM6,279.00

Add to Cart:

Confidently take reliable readings with the True-rms, Fluke 355 and 353 digital clamp meters; the tools of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements. 

Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians.

Features and benefits of the Fluke 355

  • Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc
  • The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
  • CAT IV 600 V, CAT III 1000 V rating for added user protection
  • In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
  • High voltage measurement of 1000 V ac + dc true-rms, 600 V ac, and 1000 V dc allows the user to perform multiple tests with only one tool (355 only)
  • Resistance to 400K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter. (355 only)
  • Accurately measure frequency up to 1 kHz for optimum troubleshooting
  • Quickly analyze readings using the MIN, MAX, and AVG functions
  • A large backlit display allows for easy visibility in low-lit areas
  • Use the display hold feature to capture readings even when the display cannot be viewed
  • Use the low-pass filter to smooth out noisy loads and stabilize readings

Electrical specifications

Current measurement dc and ac 10 Hz to 100 Hz

Range : 40 A

 Resolution: 10 mA
Accuracy, A: 1.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF: 2.50 A
Trigger Level for Hz Filter ON: 0.50 A

Range : 400 A

 Resolution: 100 mA
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF: 2.5 A
Trigger Level for Hz Filter ON: 2.5 A

Range : 2000 A; 1400 ac rms

 Resolution: 1 A
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF: 8 A
Trigger Level for Hz Filter ON: 8 A

 

Crest Factor (50/60 Hz)

Range : 40 A

 Crest Factor* : 2 @ 33 A, 2.4 @ 27 A

Range : 400 A

 Crest Factor* : 2 @ 330 A, 2.4 @ 270 A

Range : 2000 A; 1400 ac rms

 Crest Factor* : 2 @ 1000 A, 2.4 @ 833 A

 

Current measurement ac 100.1 Hz to 1 kHz

Range : 40 A

 Resolution: 10 mA 
Accuracy > 10 A : 3.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF : 2.50 A
Trigger Level for Hz Filter ON : 0.50 A

Range : 400 A

 Resolution: 100 mA 
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF : 2.5 A
Trigger Level for Hz Filter ON : 2.5 A

Range : 2000 A; 1400 ac rms

 Resolution: 1 A 
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF : 8 A
Trigger Level for Hz Filter ON : 8 A

 

Voltage measurement (355 only) dc and ac 10 Hz to 100 Hz 
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)

Range : 4 V

 Resolution: 1 mV 
Accuracy: 1 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V

Range : 40 V

 Resolution: 10 mV 
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V

Range : 400 V

 Resolution: 100 mV 
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V

Range : 600 V ac rms

 Resolution: 1 V 
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V

Range : 1000 V dc

 Resolution: 1 V 
Accuracy: 1 % rdg + 5 digits

 

Voltage measurement (355 only) ac 100.1 Hz to 1 kHz 
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)

Range: 4 V

 Resolution: 1 mV
Accuracy: 3 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V

Range: 40 V

 Resolution: 10 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V

Range: 400 V

 Resolution: 100 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V

Range: 600 V ac rms

 Resolution: 1 V
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V

 

Ohms measurement (355 only)

Range: 400 ?

 Resolution: 0.1 ?
Accuracy: 1.5 % + 5 digits

Range: 4 k?

 Resolution: 1 ?
Accuracy: 1.5 % + 5 digits

Range: 40 k?

 Resolution: 10 ?
Accuracy: 1.5 % + 5 digits

Range: 400 k?

 Resolution: 100 ?
Accuracy: 1.5 % + 5 digits

 

Continuity beeper (355 only)

 

 On at ≤ 30 ?

 

 Off at ≥ 100 ?

 

Frequency measurement

Measurement range

 5.0 Hz to 1 kHz

Resolution

 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)

Accuracy – 5.0 Hz to 100 Hz

 0.2 % + 2 counts

Accuracy – 100.1 Hz to 1 kHz

 0.5 % + 5 counts

Trigger level

 Refer to current and voltage tables

 


*Add 2 % to error spec for CF > 2

General specifications

Batteries

 

 Six 1.5 V AA NEDA 15 A or IEC LR6

 

Battery life (with typical usage, backlight off)

 

 100 hours

 

Test leads

 

 Rated to 1000 V

 

Weight

 

 .814 kg (1.8 lb)

 

Jaw size

This product was added to our catalog on Friday 01 August, 2014.

Who's Online

There currently are 436 guests online.
Your IP Address is: 18.97.9.172